Ressources et utilitaires

Scoring systems for ICU and surgical patients:

MPM - 24h 
(Mortality Probability Models)


Variables (Help) Values (1 if yes, 0 otherwise) Beta
Coma (Glasgow 3-5) (Help)
Cancer part of present problem
Emergency admission
Probable shock
Urine output < 150 mL / 8 h
Infection confirmed
Prothrombin time > N + 3 sec
Creatinine > 2.0 mg/dL ( >177 micromol/L)
PaO2 < 60 mmHg ( < 7.98 kPa )
FIO2 > O.5
Surgical service at 24 h
Number of lines (Help) Logit =
Logit = Sum ( values * beta) + age * 0.044142 + Hours * 0.026336 + Lines * 0.15376 - 6.5288
Predicted death rate = (eLogit) / (1 + eLogit)
Hours of mechanical ventilation
Age
Predicted Death Rate :

 

Ref : Lemeshow S et al. Refining intensive care unit outcome prediction by using changing probabilities of mortality. Crit Care Med. 1988;16:470-477  

 

 

 

Patients excluded :

Coronary care
Cardiac surgery
Burn patients
Age < 14 years

Constant ( -6.5917 ) has been subsequently substituted by (-6.5288) (personal communication from S. Lemeshow)

Back to MPM 24

Eyes Open Verbal Motor
Spontaneous
To speech
To pain
Absent
Converses / Oriented
Converses / Disoriented
Inapropriate
Incomprehensible
Absent
Obeys
Localizes pain
Withdraws (flexion)
Decorticate (flexion) rigidity
Decerebrate (extension) rigidity
Absent

Glasgow=

Back to MPM 24

 

Back to MPM 24

Number of lines :

Arterial and i.v. lines
Endotracheal or tracheostomy tube
Foley catheter
Pacing wires (counted as 1 line)
Chest tubes (counted individually)
NG tube
Drains, sumps
The abdomen is considered in quadrants with all drains / sumps in a particular quadrant counted as one "line"
"Texas" catheters are excluded